Call(904) 920-5495

Local Gas Fireplace Repair in Jacksonville

Pilot going out or burner not lighting? Local gas fireplace specialists find the failed part on a free inspection and replace it.

  • Fully licensed and insured
  • Locally owned
  • Family owned and operated
  • Same-day service

Get Your Free Inspection

Get a quote for chimney and fireplace repair and installation in Jacksonville.

Quicker by phone? Call (904) 920-5495

Call our chimney crew

(904) 920-5495 Free Inspection

Why choose us

When a gas fireplace will not light, one tired part is usually the cause and the rest of the appliance is fine. Our gas fireplace experts, from a local family business, test the pilot, sensor, valve and ignition in order, show you the reading that proves the fault, and replace the part the maker lists for your model. The price is written before we order, and the repair carries our workmanship warranty. Call (904) 920-5495 and we will bring the likely parts.

Gas fireplaces tested by the local chimney and fireplace pros

  • Locally owned in Jacksonville
  • Family owned and operated
  • 100% satisfaction guaranteed
  • Free inspection and estimate
  • Same-day service available
  • 10% off any service
  • Same-day serviceSame-day visits happen when the calendar allows, and we bring the parts your rating plate points to.
  • Upfront pricing, no hidden feesThe failed part, the reading that proved it and the price are written down before anything is ordered.
  • Workmanship warrantyEvery repair uses the maker's listed part and carries our workmanship warranty.

Gas fireplace repair work we do

Gas fireplace repair covers units that will not light, will not stay lit or burn wrong, plus the yearly service the manuals call for. Our gas fireplace pros, from a business one local family owns, test the pilot, sensor, valve and ignition in order during a free inspection, show you the reading that proves the fault, and replace that part.

  • Thermocouples, thermopiles and flame sensors tested and replaced
  • Clicking igniters and dead ignition modules fixed
  • Sooty glass and lazy yellow flames corrected at the burner
  • Blowers that hum, rattle or quit, cleaned or replaced
  • Scheduled service to the manual, with gas pressures checked
  • Propane and natural gas units both covered

How we repair a gas fireplace

  1. Rating plate read, fault watched

    The plate gives the maker, the model and the gas, and we watch the unit try to do what you called about.

  2. Meter and manometer readings

    Thermocouple, thermopile or flame rod output and the gas pressures are checked against the maker's chart.

  3. Listed part fitted, leak checked

    The failed part is replaced from the maker's list, and every connection opened gets a leak-detection solution.

  4. Burner, logs and vent set right

    Ports are cleaned, the logs go back on the diagram and the vent is checked before we light it with you.

10% off any service booked within 72 hours of inspection

Pilot, valve or ignition, the gas fireplace repair you book within 72 hours comes 10% off.

Repair the part or replace the unit?

Most gas fireplaces need one part. A few are past the point where parts are made, and we say so.

What we findThe right fixWhat we also check
What we findWeak thermocouple or thermopile readingThe right fixReplace the pilot assembly partWhat we also checkThe pilot flame against its drawing
What we findGood readings, burner still offThe right fixTest the switch, the wiring and the valveWhat we also checkInlet and manifold pressure at the test ports
What we findLow inlet gas pressureThe right fixA job for the gas utility, propane supplier or gas contractorWhat we also checkThat nothing is adjusted around a supply fault
What we findControls that were under waterThe right fixReplace the control parts, as the manuals requireWhat we also checkThe valve and module, never dried and relit
What we findParts no longer madeThe right fixReplace the fireplaceWhat we also checkVenting and framing for a new listed unit

Parts from the maker's list for your unit

Thermocouples and thermopiles
Millivolt parts that prove the pilot flame, replaced from the maker's parts list.
Ignition modules, electrodes and flame rods
For electronic ignition, each with its own part number.
Gas valves
Replaced only after the parts around them test good, then pressure and leak checked.
Logs and ember material
Set back on the numbered diagram so the flames do not strike the logs.
Glass gaskets and barrier screens
From the maker, since the glass is part of a sealed unit's seal.

What a gas fireplace repair estimate depends on

  1. Which part failed

    A thermocouple is priced very differently from a gas valve or an ignition module.

  2. Parts on hand or ordered

    Common parts ride on the truck. Others are ordered for your model.

  3. Standing pilot or electronic

    Electronic ignition has more parts to test and replace.

  4. Service items found

    A worn gasket or a termination that needs attention is listed as an extra item.

  5. Other trades

    Gas piping or wiring work is named for the gas contractor or electrician.

Checking the outside vent after storms

The outside vent termination is checked for corrosion, damage and obstruction. A blocked opening can affect the vent system, so the inspection includes the exposed components rather than stopping at the indoor controls.

Storms reach the controls too. The manuals require any control part that has been under water to be replaced, so after a flood or a heavy storm, a gas fireplace is checked before it is lit again.

What a free gas fireplace inspection covers

  1. The failed part, named, with the maker's part number
  2. Thermocouple, thermopile or flame sensor readings against the service figures
  3. Inlet and manifold gas pressure compared with the rating plate
  4. A leak check on every connection we open or replace
  5. Burner, pilot, logs and ember material cleaned and set to the diagram
  6. Glass, gasket and barrier screen checked for fit and damage
  7. Vent run and outside termination checked for blockage and spillage
  8. Work for another trade, such as gas supply or wiring, named separately

Gas fireplace repair questions

Can my gas fireplace be fixed today?

Same-day service is on offer when the calendar has room. Call (904) 920-5495, read us the rating plate, and we will bring the parts most likely to be needed.

Do you work on propane fireplaces?

Yes. Propane units use the same controls with different orifices and pressures, and we check the rating plate first. The tank and supply line belong to your propane supplier.

Are propane and natural gas fireplaces both assessed?

Yes. Tell us which fuel the fireplace uses and its model, if known, when arranging the visit. The inspection and written quote cost nothing; call (904) 920-5495 to book an assessment.

Can you still get parts for an older gas fireplace?

Often, through the maker or its parts distributors, and we check the list for your model before quoting. If a part is gone, you hear that and your options before paying for anything.

Will I see the price before any part is ordered?

Yes. The failed part, the reading that proved it and the price come first, in writing, with nothing added at the install.

Should I keep relighting a pilot that drops out?

Leave it off until we have tested it. A pilot that drops out is the safety system doing its job, and the fault behind it is usually one part. If you ever smell gas, leave the house and call the gas utility from outside first.

When a gas fireplace acts up

  • Pilot lights, then goes out

    The flame is not proving to the valve. We read the thermocouple or flame rod with a meter before replacing anything.

  • Igniter clicks and nothing lights

    The spark gap, the pilot orifice or the gas supply. The maker's flow chart shows which one.

  • Pilot lit, burner will not come on

    A good thermopile reading points to the switch, the wiring or the valve itself.

  • Tall yellow flames and sooty glass

    Blocked ports, logs off their diagram or the air setting. The flame is corrected before the glass is cleaned.

  • Blower humming, rattling or silent

    Dust on the wheel comes first, then the bearings or the thermal switch.

  • Remote or wall switch does nothing

    Batteries, pairing and the switch circuit at the valve are tested in turn.

Set up a free gas fireplace inspection

Have a local pro read your rating plate and test each part, with the price written before any order.

Free Inspection

Call the chimney and fireplace experts

(904) 920-5495

Free inspection and written estimate

Full service details

If you smell gas, leave first

A gas smell is not a repair call. Leave the house, and from outside call your gas utility, or 911 if you cannot reach them. On the way out, do not switch lights or appliances on or off and do not use a phone indoors, which is the same instruction printed in gas fireplace manuals. Once the utility has cleared the house, we can find out why it happened. A carbon monoxide alarm near the bedrooms covers the risk you cannot smell.

Three complaints, three systems

A gas fireplace not working can mean one that will not light, one that will not stay lit or one that burns wrong. Not lighting is an ignition or supply problem. Not staying lit is a flame-proving problem in the pilot flame or the thermocouple, thermopile or flame rod. Burning wrong lives in the ports, the log placement, the air setting or the venting. The checks a homeowner can safely make first are in our guide for when a gas fireplace won't turn on.

  • Gas fireplace pilot light repair, after a meter test of the flame sensor
  • Gas fireplace thermocouple replacement when its output reads below the maker's figure
  • Gas fireplace ignitor replacement and ignition module faults
  • Gas fireplace valve replacement, followed by pressure readings and a leak check
  • Gas fireplace blower repair, from a noisy fan to a dead switch
  • Fireplace blower replacement with the maker's own part
  • Gas fireplace remote repair for handsets, receivers and wall switches
  • Gas fireplace insert repair, including the vent connection
  • Gas log repair, with cracked logs replaced and the set put back on its diagram
  • Propane fireplace repair, with the tank and supply left to the propane supplier

Standing pilot and electronic ignition

On a standing-pilot unit, a thermocouple in the pilot flame makes a small voltage that holds the valve's safety magnet open, and a thermopile makes enough to open the main valve through the switch. That is the flame safeguard section 602.2 of the Florida Building Code, Fuel Gas requires, applied to vented gas fireplaces by sections 604 and 605. We read the output with a meter and compare it with the maker's chart.

Electronic ignition sends a spark to light the pilot and proves the flame through a flame rod before opening the main valve. The checks follow the maker's flow chart, from power to spark, gas at the pilot and a steady blue flame on the rod.

Pressure, leak and spillage checks

Inlet and manifold pressures are read at the valve's test ports and compared with the rating plate, and low inlet pressure is a supply problem for the utility, the propane supplier or a gas contractor. Every connection opened is checked with a leak-detection solution, the method the manuals specify. On a B-vent unit we check that exhaust goes up the vent, and a spill switch that trips is reporting a venting fault and is never bypassed.

Yearly gas fireplace maintenance

Gas fireplace manuals call for the burner system and venting to be inspected once a year by a qualified service person, and our annual gas fireplace service is built around that. The burner ports and pilot are cleaned, the logs go back on the maker's diagram, the glass gasket and barrier are checked, the blower is cleaned and the vent is walked to its termination.

Between them, the gas fireplace cleaning and the inspection of burner and vent take one visit. Some people call it a gas fireplace tune-up, and on a working unit it finds slow faults before they put the fire out. An insert gets the same gas insert service, plus a look at the liner connection at the top of the chimney.

Listed parts and where other trades begin

A vented gas fireplace is listed to ANSI Z21.88 as a heater or Z21.50 as a decorative appliance, so valves, pilots, igniters and logs come from the maker's parts list, and a change of gas is made only with the maker's conversion kit. Cracked glass is fireplace glass replacement. Vent-free units get ventless gas fireplace repair.

The gas piping that feeds the shutoff valve belongs to a gas contractor, the utility or the propane supplier, and wiring to an electrician. Whoever you hire should name the failed part and the reading behind it, and as a gas fireplace repair company we put both in writing. Call (904) 920-5495 or book a free inspection online.

Chimney and fireplace guides

All Guides

Call (904) 920-5495