We read the rating plate first, because the model and the gas type decide the parts.

  • Same-day serviceWhen the schedule has a gap, a gas fireplace in Bayard that will not light can be looked at the same day.
  • Upfront pricing, no hidden feesYou see the reading that proved the fault, the part and its price in writing, and then you decide.
  • 100% satisfaction guaranteedIf the fireplace still will not light or stay lit after our repair, we come back.

After water reaches the controls

Gas fireplace manuals are direct about water. A unit whose control system or gas valve has been under water is not to be used until a service technician has inspected it and replaced every control part and gas control that was wet. Drying them out and relighting is not an option they allow, because corrosion inside a valve does not show from outside. After flooding at the Bayard house, we inspect, list each part that was below the water line, and replace them from the maker's parts list before the unit runs again. The diagnosis visit in Bayard is free, and we bring the likely parts; call (904) 920-5495.

Bayard does not reach the coast. Bayard is a neighborhood within the City of Jacksonville.

Pilot, ignition, burner and vent

  • Pilot orifice cleared of webs and scale
  • Flame rod and spark electrode checked on electronic units
  • Blower and its thermal switch tested
  • Failed part on your Bayard unit named with its reading

Plate, readings, part, test burn

  1. Rating plate and symptom

    We read the maker, model and gas type, then watch the unit try to do what you called about.

  2. Readings against the chart

    Thermocouple, thermopile or flame rod output and the gas pressures are measured and compared with the manual.

  3. Failed part replaced

    The part that tested bad is replaced with the maker's listed part, and the burner and logs are set right.

  4. Test burn and vent check

    The unit runs through a full cycle, and the vent termination outside is checked before we go.

Gas pressure at the valve in Bayard

A gas valve has test ports on its inlet and outlet sides. A manometer on each shows whether gas is arriving at the right pressure and leaving at the right pressure.

Low inlet pressure in Bayard points to the supply, which is the gas contractor's or the utility's side.

10% off any service booked within 72 hours of inspection

A yearly gas fireplace service is a service too, and it comes 10% off.

The thermopile and the switch circuit

A thermopile is a bundle of thermocouple junctions wired together, and its larger output does more than hold the valve open: it powers the valve's main operator through the wall switch or remote receiver. That makes the switch circuit part of the fuel system. A long wire run, thin wire, a corroded terminal or a worn switch can each drop enough voltage that the burner will not come on. The maker's chart gives the readings to take at the valve terminals, with the switch open and closed, and a short jumper across the switch shows whether the switch or the wire is at fault.

A spill switch doing its job

A natural vent gas fireplace can carry a spill switch, a heat-sensing switch near the draft hood. If exhaust spills back into the room instead of rising up the vent, the heat trips the switch and the valve shuts, and on some units the switch has to be reset by hand.

A trip is a message about the vent: a blockage, a cold vent that has not started to draw, a vent that is too short or too long, or a house pulling air through it. We find that cause and fix it. The switch is tested and replaced if faulty, and it is not bypassed.

Checking the vent termination outside

The vent termination is the part of a gas fireplace that sits outside, out of sight from the room, and it is where trouble from outside starts. Nests, leaves and wasp activity can block its openings, a shrub can grow into the clear zone in front of it, and a knock from a ladder or a mower can dent the cap.

On a direct-vent unit, a blocked or damaged termination can also let exhaust into the intake. On service we walk outside, check the cap, its screen and its clearances, and note any growth or damage. Plants are trimmed back to the clear zone the manual sets.

Readings, parts and the vent check

  1. Pilot assembly cleaned, adjusted or replaced as one listed part
  2. Flame rod, spark electrode and ignition cable checked for wear
  3. Control module taken through its full lighting sequence
  4. Logs lifted, cleaned and returned to their numbered positions

Gas fireplace questions from Bayard

Can my gas fireplace be used with cracked glass?

No. The manuals do not allow a sealed unit to run with cracked, broken or missing glass, because the glass is part of the seal that keeps exhaust out of the room. Leave it off until the maker's glass assembly is fitted.

Does a service visit include cleaning the glass?

Yes, after the burner, logs and embers are set right. Soot on the glass comes from the flame, so the flame is corrected first.