Local Gas Fireplace Insert Specialists in Jacksonville
Swap an open wood fireplace for a sealed gas heater. Local, family-owned installers and a free inspection.
- Family owned and operated
- Free inspection and estimate
- Same-day service available
- Upfront pricing, no hidden fees
Get Your Free Inspection
Get a quote for chimney and fireplace repair and installation in Jacksonville.
Request received
Thank you. We will call you shortly to set a time.
or call (904) 920-5495
Why Choose Us
Gas insert experts who clean the chimney first
- Locally owned in Jacksonville
- Family owned and operated
- 100% satisfaction guaranteed
- Free inspection and estimate
- Same-day service available
- 10% off when you book today
A gas insert gives you heat at the flip of a switch from a fireplace you are tired of tending. As a family-run local company, we check and clean the chimney, run a listed vent kit to the top, and fit the insert and surround to its listing. One written price names every trade involved, and first-timers save 10% on the install. Start with a free inspection by calling (904) 920-5495.
- Free inspection and estimateWe check the chimney top, the throat and your opening size for free before an insert is ordered.
- Upfront pricing, no hidden feesThe insert, vent kit, surround and cleaning are on one written price, along with who brings the gas and power.
- 10% off first serviceFirst-time customers save 10% on the insert installation.
Our Services
Everything a gas insert install includes
A gas fireplace insert is a sealed firebox with a glass front that fits into your existing fireplace and vents through two pipes run up the old chimney. Our gas insert professionals clean and check the chimney, run the listed vent kit and fit the surround. Owned by one local family, we check on a free inspection whether your fireplace can take an insert.
- Chimney cleaned and checked before any liners go in
- Co-linear or co-axial vent kit run to the top
- Insert sized to your opening and its listed clearances
- Surround panels trimmed to fit, with mantel clearance checked
- Gas and power hookups assigned to the right trades
- Start-up checks and a walk-through on the controls
How It Works
How a gas insert gets installed
-
Check the chimney and opening
We measure the opening and the face, look at the chimney top, and confirm the fireplace's own manual allows an insert.
-
Clean the old flue
A chimney that vented wood is cleaned before a gas appliance connects to it, and the damper is removed or fixed open.
-
Vent kit up the flue
Co-linear or co-axial liners go up the flue within the maker's rise and offset limits and end at the listed termination cap.
-
Set, trim and light it
The insert and surround go in, gas and power are connected by the named trades, and we light it with you and go over the controls.
10% off your first service when you book today
Done tending wood fires? Book your gas insert install today and take 10% off the first service.
Your Options
Co-linear or co-axial venting for the insert
The shape of the old flue and the insert's manual decide which vent kit goes up the chimney.
Free Inspection
Gas insert fit check, item by item
- Fireplace and chimney condition, and the cleaning needed before liners go in
- The insert's listing, minimum opening size and clearances
- The liner kit: co-axial or co-linear, sizes, length and termination
- Vertical rise, offsets and any restrictor setting from the vent rules
- Surround and trim sizing, and the clearance to the mantel and side trim
- Gas supply and any electrical supply, and who does each
- The damper, removed or fixed open, and the top plate and cap
FAQ
Gas fireplace insert questions
Does the old chimney get cleaned before a gas fireplace insert install?
Yes. Florida's fuel gas code calls for a chimney that vented solid fuel to be cleaned before a gas appliance is connected, so we clean it, then run the liners.
Will the insert run when the power goes out?
It depends on the ignition. Standing-pilot units can light without house power, though the fan will not run, and your model's manual says which it has.
How many trips does a gas insert install need?
Usually one visit once the chimney is ready and the gas line is in. Your estimate spells out the order of work and who comes when.
Arlington homeowner. Can you put in a gas insert?
Yes. Call (904) 920-5495 for a free inspection and written estimate, and tell us whether the house has natural gas or propane.
What is on the insert estimate?
The insert, the vent kit, the surround, cleaning and any repairs, plus who brings the gas and power. The total does not move without your approval.
Common Problems
Reasons homeowners choose a gas insert
Wood fires are more work than you want
A sealed gas insert lights at a switch or remote and heats the room through the glass. We check your fireplace can take one first.
Cold drafts from the fireplace opening
An open flue pulls room air out between fires. The surround closes the opening, and a top plate and cap close the old flue.
Old fireplace, no idea if an insert fits
Each insert lists a minimum opening size and clearances. We measure your opening and the mantel first, so the insert you order fits.
Worried about the hot glass with kids
Inserts built since the 2015 barrier rule in ANSI Z21.88 carry a mesh screen ahead of the glass, and it goes back on after the install.
Gas Fireplaces
More gas fireplace installation services
Find out free if your fireplace takes an insert
Our local insert specialist checks the opening, the flue and the chimney top, then writes one price for the whole job.
Free InspectionFull service details
How a direct-vent gas insert works
Direct-vent gas insert installation puts a sealed firebox with a glass front into an existing fireplace opening. It draws combustion air from outdoors and sends exhaust outdoors through its own pipes, so room air does not feed the flame. These inserts are listed to ANSI Z21.88 as vented gas fireplace heaters, and the listing and manual set everything from the smallest opening they fit to the mantel clearance.
Venting a gas insert through the old chimney
In a co-linear system, two flexible liners, one for intake and one for exhaust, run side by side to a co-linear termination, and one maker's kit uses a 3-inch intake and a 4-inch exhaust liner. In a co-axial system the exhaust pipe runs inside the intake pipe. The manual sets the vertical run, the offsets and any restrictor, and the same maker advises stainless liners where the vent cannot be reached later.
Section 503.5.6 of the Florida Building Code, Fuel Gas, calls for a chimney that vented solid fuel to be examined and cleaned before a gas appliance connects to it. The damper is removed or fixed open, and per the maker's instructions the co-linear vent may run only inside a solid-fuel fireplace and chimney, with no wood-burning appliance sharing the flue.
Surround, barrier screen and the trades on a gas insert
The surround comes in sizes, so we measure the opening and the face before ordering, and the listing sets the clearance to the mantel and side trim. Units built since the barrier rule in ANSI Z21.88 and Z21.50 took effect in 2015 ship with a mesh barrier ahead of the hot glass, and it stays on.
Gas piping is its own trade under NFPA 54 and the Fuel Gas volume, and a fan or electronic ignition may need an outlet, which is electrical work. The estimate names who does each. With a gas insert in a fireplace, installation in a factory-built unit depends on that fireplace's manual, which decides whether an insert may go in at all.
Call (904) 920-5495 and we will check, free of charge, whether your fireplace can take an insert.
Guides
Chimney and fireplace guides
-
Logs, an insert or a new unit: sizing a gas fireplace job Three gas options sit on one scale. The vent route, the gas line and the finish work then move each one along it.
-
Switching a wood fireplace to gas: log set or sealed insert A log set keeps the open fireplace; an insert seals it. Both start with a clean, sound chimney and a gas line run by the gas trade.