Call(904) 920-5495

Family-run fireplace insert installation in Arlington

A heater that fits your Arlington fireplace, installed by local experts, with our 100% satisfaction guarantee behind it.

  • Fully licensed and insured
  • Locally owned
  • Family owned and operated
  • Same-day service

Get Your Free Inspection

Get a quote for chimney and fireplace repair and installation in Jacksonville.

Quicker by phone? Call (904) 920-5495

Call our chimney crew

(904) 920-5495 Free Inspection

Insert specialists who measure first in Arlington

  • Locally owned in Jacksonville
  • Family owned and operated
  • 100% satisfaction guaranteed
  • Free inspection and estimate
  • Same-day service available
  • 10% off any service

The liner runs full length and matches the insert collar, the setup insert makers call the safest.

  • Free inspection and estimateYour Arlington firebox, chimney height and hearth are measured against the insert's manual at no charge, before anything is ordered.
  • Upfront pricing, no hidden feesEvery part of the job is priced before ordering, from repairs to the rain cap, and nothing is added without your yes.
  • 100% satisfaction guaranteedIf the insert smokes or draws poorly after installation to its manual, we come back and set it right.

Power for the insert's blower

Plenty of wood inserts carry a blower that circulates room air around the steel box and out through the grille, and the blower plugs into an outlet near the fireplace. Where there is no outlet within reach, one has to be added before the insert can run its fan.

Adding an outlet is electrical work, done by an electrician, and the estimate names that part of the job separately so the install day runs in order. Want an insert with a blower in Arlington? Plan the power with us at (904) 920-5495.

Arlington sits in Duval County. Arlington is inland.

What fireplace insert installation covers in Arlington

  • Listed wood inserts installed to their manuals
  • Dampers locked open or removed for the liner
  • Outside air kits through the old ash chamber
  • Model, liner and clearances recorded for your Arlington house

From tape measure to first fire in Arlington

  1. Measure against the manual

    Firebox, chimney height, hearth and clearances are checked against the insert's table before ordering.

  2. Repair and clean first

    Fireplace repairs are made and cured, and the flue is cleaned before the liner goes up.

  3. Liner, plate and cap

    A listed stainless liner runs to the top, closed with a top plate and a rain cap.

  4. Set, seal and fire

    The insert and surround go in as the manual directs, and the first fire is run with you.

Draft on an inland chimney in Arlington

Well back from the coast, an insert's performance comes down to the chimney: its height and the liner size. One maker sets a 15-foot minimum height for its model.

We measure the chimney in Arlington before recommending a unit.

10% off any service booked within 72 hours of inspection

The insert, the liner and the labor are all discounted.

Stainless liners and the UL 1777 listing

Chimney liners are tested and listed under UL 1777, and an insert liner should carry that listing for its use. For an insert in a factory-built fireplace, one maker requires the full-length stainless liner to meet the Type HT rating, tested to 2,100 degrees Fahrenheit, and to be fixed at both the collar and the chimney top.

We order liners by listing, diameter and length, and the liner's own instructions set its bend limits, its insulation where required and its fittings. The liner make and listing go on the ticket beside the insert's model, so anyone servicing it later knows what is in the flue.

Closing the top of the old flue

Above the chimney, a full liner ends in a top plate and a rain cap. One maker's instructions have the plate trimmed to fit the existing flue with an overlap of 1 to 1 1/2 inches on each side, seated firmly on the flue lining, screwed to the liner collar and sealed with RTV silicone.

The cap then goes on the end of the liner. The plate keeps rain and animals out of the space around the liner, and the cap keeps them out of the liner itself. Both are listed on the estimate with the liner, and a cracked flue top that the plate would sit on is noted before the work.

When the surround is sealed to the face

Sealing the surround panels to the fireplace face is not automatic. One maker seals them when the insert draws its air from outdoors, and leaves them unsealed when it draws room air, so enough air reaches the fire through the fireplace cavity.

For a factory-built fireplace, the same maker requires the surround or the damper area around the liner to be sealed so room air does not enter the chimney cavity. We follow the manual of your model and your fireplace type rather than a habit, and the ticket notes how the surround was set so a later service visit leaves it the same way.

Fireplace, flue and hearth on paper first

  1. Flue cleaned and checked for obstructions before the liner goes up
  2. Full-length stainless liner, listed to UL 1777, matched to the collar
  3. Mantel, side facing and side wall clearances measured to the label
  4. EPA Step 2 label read and the model and serial number recorded

Wood insert questions from Arlington

Can I keep my mantel?

Often, if it clears the distance on the insert's label. When it does not, you pick a model with smaller clearances or rework the trim, and we measure before you order.

Do you sell the insert or only install it?

We install to the insert's listing, and the estimate spells out which parts we supply, from the liner to the cap. Call (904) 920-5495 and tell us whether you already have a model for the fireplace in Arlington.

A wood insert that fits your Arlington fireplace

A free insert inspection in Arlington is one call to (904) 920-5495, and you save 10% on the install by booking within 72 hours of it.

Free Inspection

Call the chimney and fireplace experts

(904) 920-5495

Free inspection and written estimate

Call (904) 920-5495