Direct vent and B-vent service for Northside gas fireplaces

Direct-vent or B-vent, your Northside run is checked against the maker's rules and the fuel gas code before any pipe is replaced.

  • Fully licensed and insured
  • Locally owned
  • Family owned and operated
  • Same-day service

Get Your Free Inspection

Get a quote for chimney and fireplace repair and installation in Jacksonville.

Quicker by phone? Call (904) 920-5495

Call our chimney crew

(904) 920-5495 Free Inspection

Gas fireplace venting experts for Northside homes

  • Locally owned in Jacksonville
  • Family owned and operated
  • 100% satisfaction guaranteed
  • Free inspection and estimate
  • Same-day service available
  • 10% off any service

In Northside, vent work begins at the collar and follows the run to the cap.

  • Free inspection and estimateThe vent on your Northside gas fireplace is traced from the collar to the cap and measured against the code at no charge.
  • Upfront pricing, no hidden feesEach section, fitting and reroute is priced on its own line before any pipe is cut or replaced.
  • 100% satisfaction guaranteedIf the flame, the draft or the shutdown problem is not fixed by the vent repair we quoted, we come back.

The cap sits under a soffit

Wall caps tucked under the eaves can push exhaust up into a vented soffit and from there into the attic. Makers set separate distances for vented and unvented soffits above a cap. Exhaust drawn into an attic is not something to leave until the next season.

The cap's position is measured against the maker's chart, and where it sits too high under the eaves, it is rerouted. Gas fireplace vent tucked under the eaves on your Northside house? Book a free check at (904) 920-5495.

The coastline lies beyond Northside. Northside is one of the named neighborhoods of Jacksonville.

What gas fireplace venting covers in Northside

  • Blocked terminations cleared after storms
  • New vent routes drawn before any cutting
  • Your Northside vent traced from collar to cap
  • Roof covering work named for a roofer

How gas fireplace vent work runs

  1. Identify the system

    The manual and pipe markings tell us the vent type, size and maker.

  2. Trace the run

    With the unit off and cool, we follow the vent and check joints, supports and clearances.

  3. Repair with listed parts

    Joints are reseated, damaged sections replaced and crowded caps moved.

  4. Test and record

    We fire the unit, check flame and draft, then note every fix.

Vent joints inland in Northside

Direct-vent joints in Northside can open after a knock from other trades working nearby.

Each joint within reach is turned and locked again where needed.

10% off any service booked within 72 hours of inspection

Fireplace shutting down? The vent job you book within three days of the trace is 10% off.

Sealed direct vent and natural-draft B-vent

Direct-vent fireplaces are closed off from the room. Every bit of their combustion air comes in from outdoors through the vent, and exhaust leaves the same way, through a pipe inside a pipe that ends at a cap on a wall or roof.

Natural-vent, or B-vent, fireplaces take their air from the room and count on hot exhaust climbing a double-wall Type B vent, with a draft hood on the appliance. The two cannot be swapped, and each has its own parts and rules. A repair keeps the system the appliance was built and listed with. Identifying which one you have is the first line on every vent estimate.

A cap under a deck or porch

Under a veranda, porch, deck or balcony, a direct-vent cap is allowed only with conditions. One maker allows it at 12 inches of clearance, and only when the space is fully open on at least two sides beneath the floor.

Enclosing the sides of a deck later can turn a legal cap into a problem, because exhaust has nowhere to go. We check how open the space is today and, where it has been closed in, reroute the vent or open the sides. The same chart keeps the cap from terminating directly above a sidewalk or driveway shared by two homes. Lattice added under a deck counts as closing it in.

Supporting and fastening B-vent

B-vent pipe has to carry its own weight without leaning on the appliance or its elbows. One maker asks for horizontal runs to be supported at least every 5 feet and for offsets to be supported so the pipe's weight does not bear on the elbows.

The same manual says not to drive sheet metal screws through the pipe's inner liner, and fastens the first section to the firebox with self-tapping screws and plumber's strap pulled taut. We check supports and fastening along the run, since a sagging run is how joints pull apart. Straps and supports come from the vent maker's parts list, not the hardware aisle.

Traced in Northside before any vent pipe is replaced

  1. Every reachable joint checked for full engagement and its lock
  2. B-vent height, horizontal length and roof cap height measured
  3. Damaged sections replaced from the listed vent system
  4. Spillage test at the draft hood with fans on and off

Before the vent is opened up

Could the vent be why my gas fireplace in Northside shuts off?

It can be. A blocked cap, a leaking inner pipe or a badly pitched run can all put the flame out. We test the vent first, then the controls.

How often should the vent be inspected?

Once a year at minimum, plus a check before first use, by someone qualified. We can put it on the calendar.

A vent that draws and seals in Northside