Call(904) 920-5495

Smoke chamber repair in Mayport, troweled smooth

We measure the smoke chamber in your Mayport fireplace against the code before choosing parging or a rebuild, free.

  • Fully licensed and insured
  • Locally owned
  • Family owned and operated
  • Same-day service

Get Your Free Inspection

Get a quote for chimney and fireplace repair and installation in Jacksonville.

Quicker by phone? Call (904) 920-5495

Call our chimney crew

(904) 920-5495 Free Inspection

Smoke chamber pros who measure before they trowel

  • Locally owned in Jacksonville
  • Family owned and operated
  • 100% satisfaction guaranteed
  • Free inspection and estimate
  • Same-day service available
  • 10% off any service

Water getting onto the shelf is traced and fixed before the chamber is coated.

  • Free inspection and estimateWe look above the damper in your Mayport fireplace, measure the chamber and write down what we find at no cost.
  • Upfront pricing, no hidden feesCleaning, resets, parging and cure time are priced line by line before the first trowel goes in.
  • Family owned and operatedA family-owned local crew does the reaching and troweling through the throat, and cleans up after itself.

A cracked prefabricated chamber liner

Some masonry fireplaces were built with a prefabricated ceramic smoke chamber liner rather than corbeled brick. The code allows its walls to slope up to 45 degrees from vertical. When the liner cracks or a section slips, the backing masonry is exposed to heat it was not built to face. Those linings were made in sections, and the joints between them are where trouble starts.

At a fireplace in Mayport, we check whether the liner can be repaired to its maker's instructions or should be parged over or replaced. The choice and its reason go on the estimate.

Mayport sits in Duval County. Kathryn Abbey Hanna Park can be found in Mayport.

Smoke chamber work we take on in Mayport

  • Loose chamber units reset in refractory mortar
  • Open joints filled before parging
  • Out-of-limit chambers rebuilt to shape
  • Your Mayport fireplace protected while we work above it

Measure, clean, reset, parge

  1. Tell us what the fireplace does

    Spilling smoke, a stale smell or grit on the damper plate tells us what to bring to the free visit.

  2. Chamber measured and mapped

    Height, width and wall slopes are measured, and each wall, the shelf and the flue transition are checked.

  3. Cleaned, reset, parged

    Soot and glaze come off, loose units are reset, joints filled, then refractory mortar goes on in layers.

  4. Cured and draft tested

    The product cures as its data sheet directs, then a small fire shows how the fireplace draws.

10% off any service booked within 72 hours of inspection

The room stays covered while we work, and the chamber job comes 10% off.

Water reaching the smoke shelf

Rain that gets into the flue runs down the tile and lands on the smoke shelf. A shelf that holds water keeps the damper frame wet and soaks the masonry below the chamber, and wet masonry does not take a parge coat well.

The water source goes on the estimate first, and we look for it at the chimney top first. The shelf is then reshaped to drain toward the firebox, and the chamber is parged once it has dried out. A parge coat laid over wet masonry traps water behind it and can blister.

Prefabricated chamber linings

Some masonry fireplaces use a factory-made ceramic smoke chamber lining, set inside the masonry. The code allows those linings a steeper wall slope, up to 45 degrees from vertical, than corbeled brick gets.

A cracked or shifted lining is repaired to its maker's instructions where they exist, or parged over with a compatible refractory product, or replaced. We check what the lining is before choosing, and the estimate says which route fits and why. A lining section that has slipped out of place is not parged over, because a coat on a moving piece cracks along the joint.

The throat and the lintel below the chamber

R1001.7 carries the masonry over a fireplace opening on a noncombustible lintel with 4 inches or more of bearing at each end, and sets how far above it the throat must start. The damper rule, R1001.7.1, asks for at least 8 inches between the top of the opening and the damper. The chamber sits on top of that arrangement.

A sagging or rusting lintel shows as cracks above the opening and gaps at the base of the chamber. We check it from below while we are looking up, since chamber work on a moving base will not last. A rusting steel lintel is written up on its own line, since repairing it affects the face of the fireplace.

Shape, walls, shelf and product, in writing

  1. Wall slopes checked against the 30 and 45 degree limits
  2. Soot and loose mortar cleaned off to bare, sound masonry
  3. Loose chamber brick reset in refractory mortar, units counted
  4. Rebuild option priced where the chamber shape is out of limits

Smoke chamber questions from Mayport

How soon can someone look at the smoke chamber in Mayport?

When a slot is free that day, yes. Tell us whether the fireplace smokes, smells or drops debris, and we will bring what the visit needs.

Why can't the sweep fix the smoke chamber?

A sweep cleans the surface that is there. Filling steps, resetting brick and troweling on refractory mortar is masonry work, and it is what makes the chamber smooth.

Smoke chamber repair from local masons in Mayport

Book the free chamber inspection in Mayport, then save 10% on the parging by booking it within 72 hours.

Free Inspection

Call the chimney and fireplace experts

(904) 920-5495

Free inspection and written estimate

Call (904) 920-5495