
Fireplace installation in Callahan by local specialists
Every installation in Callahan starts with a free visit that names the permit, the inspections and the schedule.
- Family owned and operated
- Free inspection and estimate
- Same-day service available
- Upfront pricing, no hidden fees
Get Your Free Inspection
Get a quote for chimney and fireplace repair and installation in Jacksonville.
Request received
Thank you. We will call you shortly to set a time.
or call (904) 920-5495
Why Choose Us
Local fireplace experts for new installs in Callahan
- Locally owned in Jacksonville
- Family owned and operated
- 100% satisfaction guaranteed
- Free inspection and estimate
- Same-day service available
- 10% off when you book today
Every clearance comes from the unit's manual or the code, and it is marked before framing starts.
- Family owned and operatedOne family business owns your Callahan fireplace plan, from the framing or footing to the top of the chimney.
- Free written estimatesUnit, chimney, framing, hearth, permit and any other trade sit on one free written estimate.
- Workmanship warrantyOur installation work is covered by our workmanship warranty, and the unit carries its maker's terms.
Sizing the fireplace to the room
A fireplace that suits the room leaves space in front of it. The manual for a factory-built unit sets how far furniture and curtains have to stay from its front, and the hearth extension takes floor space of its own.
A large opening in a small Callahan living room can crowd the seating and overheat the wall above it. We measure the room with you, mark the hearth and the clear zone on the floor with tape if that helps, and look at a smaller unit when the room calls for one. A fireplace should fit the room it serves. A free planning visit for a new fireplace in Callahan is one call away at (904) 920-5495.
About 25 miles, as the crow flies, separate Callahan from Jacksonville. The county for Callahan is Nassau County.
What's Included
Fireplace installation work we take on in Callahan
- Unit and chimney system named by maker and model
- Framing built to the installation manual's dimensions
- Attic insulation shield where the pipe passes through
- Old worn-out unit removed and hauled away
How It Works
Walk it, permit it, build it, hand it over
-
Route walked, hearth to roof
The room, the attic and the roof are checked for a clear chimney path before any unit is chosen.
-
Unit and chimney system chosen
A listed factory-built system from one maker, or a masonry fireplace on its own footing.
-
Framed, built and inspected
Framing and clearances follow the manual or the code, and the inspector sees them before the walls close.
-
Hearth, air supply and handover
The hearth extension and outside air go in, and we explain how to run the break-in fires.
Local Conditions
Shields and firestops for Callahan installs
Where a factory-built chimney passes an insulated ceiling, the code calls for a steel insulation shield around it, and every floor and ceiling gets a listed firestop.
We fit both on installs in Callahan and leave them visible for the inspector.
10% off your first service when you book today
If this is your first job with us, the installation is 10% off.
Rumford fireboxes, tall and shallow
A Rumford fireplace has a tall opening, a shallow firebox and angled side walls that throw heat into the room. The code makes room for it: a Rumford firebox may be as shallow as 12 inches, as long as it meets the other proportions the code sets for the design, including a throat of at least one-twentieth of the opening's cross-sectional area. A Rumford is a masonry build, and it is laid out from those proportions rather than from a standard firebox plan.
If you like the look, we draw it as a separate option. Its tall opening can push the opening area past 6 square feet, which enlarges the required hearth extension.
Taking out the old unit
Removing a failed factory-built fireplace is a job of its own. The facing comes off first, then the unit is disconnected from its chimney, unfastened from the framing and slid out in one piece where the framing allows.
When the chimney is being replaced too, it comes down section by section from inside, with its firestops and shield. The old framing is measured against the new unit's manual, and the opening is resized where the dimensions differ. Debris leaves the house bagged, and you know in advance what happens to the finished wall around the opening. The old unit's rating plate is kept with your paperwork.
Carrying the weight
Light as a factory-built fireplace is, the chimney, a stone hearth and the finish around the opening add up. The code requires any framing that supports a factory-built chimney to be designed for the added load. Where the chimney hangs from roof or ceiling framing, or an offset puts weight on a single joist, the framing is sized and headed off to carry it.
A heavy hearth set on a framed floor gets the same attention. The plan shows what carries each load, and the inspector sees it before the ceiling closes. Framing sizes come from the load.
Free Inspection
Route, unit, permit and hearth on paper
- Clearance to combustibles marked on each side of the unit
- Removal of the failed unit and any pipe that no longer fits
- Roofer, electrician or other trades named with their part of the job
- Permit application and each inspection on the schedule
FAQ
New fireplace questions from Callahan
Do I need a permit for a new fireplace?
Yes. A permit is required for this work under the Florida Building Code, and the local building department inspects it before the walls close and again at the end. The permit and those inspections appear in the schedule on the estimate.
Can the new fireplace use my old chimney pipe?
Only if the new unit's manual lists that pipe. If it does not, the chimney is replaced with the system the new unit was tested with.
Our Services
More services in Callahan
-
Chimney Waterproofing Brick that soaks up rain treated with a breathable repellent.
-
Chimney Sweep and Chimney Cleaning Soot and early creosote brushed out of the flue, smoke chamber and firebox.
-
Gas Fireplace Installation Direct-vent and B-vent gas fireplaces, framed and vented to the manual.
-
Chimney Flashing Repair The metal joint between roof and chimney, re-formed so rain runs past it.
-
Chimney Chase Cover Replacement A rusted or ponding chase top replaced with one that drains.
-
Chimney Cap Installation and Replacement Rain, animals and embers kept out of the flue by a fitted cap.
Learn more about fireplace installationAll services in Callahan
Add a fireplace to your Callahan home
Our installation pros walk the route from hearth to roof in Callahan and draw the plan. Call (904) 920-5495.
Free Inspection