Call(904) 920-5495

Gas log sets installed in Brentwood fireplaces

Vented logs with the damper clamped open, or vent-free logs where the room allows, installed in Brentwood to the listing.

  • Fully licensed and insured
  • Locally owned
  • Family owned and operated
  • Same-day service

Get Your Free Inspection

Get a quote for chimney and fireplace repair and installation in Jacksonville.

Quicker by phone? Call (904) 920-5495

Call our chimney crew

(904) 920-5495 Free Inspection

Gas log experts for Brentwood homes

  • Locally owned in Jacksonville
  • Family owned and operated
  • 100% satisfaction guaranteed
  • Free inspection and estimate
  • Same-day service available
  • 10% off any service

Vent-free sets are recommended only where the room's size and use allow them.

  • Free inspection and estimateYour Brentwood firebox, flue, damper and room are measured against the set's manual at no charge before anything is bought.
  • Upfront pricing, no hidden feesSet, burner, clamp, cleaning and any repairs are priced in writing, with the gas trade's part named.
  • 100% satisfaction guaranteedIf the flame is sooty or the set will not stay lit after our installation to the manual, we come back.

Tired of wood and ash

Wood fires mean carrying logs in, waiting for the fire to catch and cleaning ash out afterward. A gas log set gives a fire at a turn of a valve or the press of a remote, in the fireplace you already have, and goes out just as quickly when you are done. No new venting is needed for a vented set in a sound fireplace.

Before recommending one, the fireplace and its flue get a close look and the firebox gets measured, since both decide which sets can go in. Ready to trade wood for gas logs in Brentwood? Book the free inspection at (904) 920-5495.

Brentwood is part of Duval County. Brentwood is an inland community.

Gas log work for Brentwood fireplaces

  • Vented log sets with permanent damper clamps
  • Fireboxes measured against the set's size table
  • Propane and natural gas sets matched to the plate
  • Yearly service set up from install day

How gas log installation runs

  1. Measure firebox and room

    Firebox, chimney height and, for vent-free sets, the room are checked against the manual.

  2. Clean and clamp

    Soot and debris come out of the fireplace, and vented sets get their permanent damper clamp.

  3. Connect and test

    Once gas reaches the valve, the set is connected, leak tested and its pressure read.

  4. Place logs and light

    Logs and embers go where the manual shows, and we light the set with you.

Which fuel the house has in Brentwood

Houses in Brentwood differ in fuel, piped gas in some and propane in others, and the set must match.

We confirm it before anything is bought.

10% off any service booked within 72 hours of inspection

Ready for gas logs? Book within 72 hours of the measuring visit and 10% comes off.

What a vent-free log set is

A vent-free log set is an unvented room heater, and the code's section 621.1 wants it listed to ANSI Z21.11.2 and set up exactly as its listing and instructions say. One maker's vent-free set, tested to that standard, may run with the flue damper closed.

That is the attraction and the limit at once: the room receives everything the flame produces. The code's rules on size, input and location follow from that, and we apply them before a vent-free set is chosen. A vent-free set is also a heater, not only a decoration, which is why its rules read like a heater's. We walk through them with you before recommending one.

Chimney height for a vented set

Vented logs rely on the chimney to carry their exhaust away, and one maker wants at least 15 feet of chimney between the hearth and the top for its vented burners.

Taller chimneys draw more strongly, which is why the same maker allows a smaller permanent damper opening as the chimney gets taller. We measure the height when we inspect the flue, and a chimney that falls short of the figure rules out that set, or calls for a different approach, before anything is ordered. The same table also accounts for factory-built fireplaces separately.

Gas pressure the set needs

Log sets have a pressure range at their inlet. One maker's vented burner needs at least 5 inches of water column on natural gas and 11 on propane for input adjustment, with maximums of 10.5 and 13, and says not to install it where the minimum is not available.

The same manual requires propane to be regulated and rules out connecting to an unregulated tank or a portable cylinder. We read the inlet pressure with the set running, and with other gas appliances in the house running too, and record the readings on the ticket.

Measured in Brentwood before a log set is ordered

  1. Firebox front width, rear width, depth and height against the set's table
  2. Damper clamp fitted permanently and the opening measured
  3. Supply pipe sized by the gas trade, with inlet pressure read at the valve
  4. Logs, embers and sand or vermiculite set exactly to the manual

Before a log set goes in

Who runs the gas line?

The gas trade: a gas fitter, the utility or your propane company. The estimate names them, and our hookup and test follow once gas is at the valve.

Can I convert my log set to propane?

It depends on the set. Some are not convertible in the field at all, and others convert with the maker's instructions. The rating plate and manual decide.

Put gas logs in your Brentwood fireplace

Done with wood fires in Brentwood? Our specialists check free which log set fits.

Free Inspection

Call the chimney and fireplace experts

(904) 920-5495

Free inspection and written estimate

Call (904) 920-5495