Local gas fireplace installation for Fernandina Beach homes

Local pros fit a vented gas fireplace to your Fernandina Beach room, route the vent to the manual and name who brings the gas. Planning is free.

  • Fully licensed and insured
  • Locally owned
  • Family owned and operated
  • Same-day service

Get Your Free Inspection

Get a quote for chimney and fireplace repair and installation in Jacksonville.

Quicker by phone? Call (904) 920-5495

Call our chimney crew

(904) 920-5495 Free Inspection

Local gas fireplace experts for new installs in Fernandina Beach

  • Locally owned in Jacksonville
  • Family owned and operated
  • 100% satisfaction guaranteed
  • Free inspection and estimate
  • Same-day service available
  • 10% off any service

Every clearance comes from the unit's manual, from the header height to the mantel depth.

  • Family owned and operatedOne family business frames, vents and starts up the unit in Fernandina Beach, and lines up the gas and electrical trades.
  • Workmanship warrantyThe workmanship warranty applies to our venting, framing and start-up, and the unit keeps its maker's terms.

One vent per appliance

Each gas fireplace gets a vent of its own, from the unit to its own termination outside. Joining a gas fireplace vent to a chimney that carries smoke from a wood fire, or sharing one vent between two gas appliances, is ruled out in the manuals. That shapes the plan in a house in Fernandina Beach that already has a wood fireplace or a gas water heater nearby, where an existing flue can look like an easy path. The new vent runs separately, with its own clearances. A shortcut through an old flue is not on the table. Picked a room for a gas fireplace in Fernandina Beach? (904) 920-5495 is the number for a free planning visit.

Amelia Island Light can be found in Fernandina Beach. Fernandina Beach sits in Nassau County.

From vent exit to first burn

  • Direct-vent or B-vent unit chosen for the room
  • Horizontal runs pitched the way the manual asks
  • Wiring for the receiver and blower run before the wall closes
  • Walk-through of your new Fernandina Beach unit and its manual

Vent out, frame, wire, start up

  1. Vent exit found first

    We find where the vent can leave the house within the manual's clearances, then pick the unit to suit.

  2. Frame and run the vent

    The enclosure and header are framed to the drawing, and the vent is run with its supports, pitch and firestops.

  3. Trades, wiring and gas

    Wiring goes in before the wall closes, and the gas contractor brings the line to the shutoff valve.

  4. Start-up and inspection

    Pressures are read, joints leak checked, the inspector signs off, and we go over the controls with you.

Siding and trim around coastal terminations

The vent maker supplies a standoff or siding shield to hold the termination away from vinyl siding. Near salt water, that trim is exposed to the same corrosion as the cap.

On Fernandina Beach homes we fit the maker's corrosion-resistant trim where it is offered.

10% off any service booked within 72 hours of inspection

Planning a vented unit? Decide inside the 72 hours and you save 10%.

Supports, thimbles and firestops

A vent run needs support along its length, at the spacing the manual sets, so joints do not pull apart over time. Where it passes an outside wall, a wall thimble or firestop from the vent maker holds the pipe centered and keeps its clearance to the framing. Where it passes a ceiling or floor, a firestop spacer does the same job.

Horizontal pipe keeps the clearance the manual lists, which on some systems is larger above the pipe than beside it. Air spaces around the pipe stay open, with no insulation packed in. Joints are locked as the vent maker's instructions show.

Wiring before the wall is closed

Remote receiver, wall switch and blower wiring are run before the finish goes on, as the manuals ask, because running it afterward means cutting into the new wall. A millivolt wall switch needs its own low-voltage wire to the valve, sized and limited in length as the manual shows.

A blower or an electronic-ignition unit needs an outlet in the location the manual gives, added by an electrician. We rough in the low-voltage wiring during framing and confirm the outlet is in place before the drywall goes up. The wire runs are labeled at both ends for whoever services the unit later.

Choosing termination parts near salt spray

Salt spray speeds up corrosion of exposed steel, and a new vent termination spends its life outdoors. Near the coast, we look at what the vent maker offers for the termination, its trim and its fasteners, including stainless or coated options where the maker lists them, and use those parts on the exterior. The termination is placed where it can be reached for rinsing and inspection, and the manual's clearances still govern its spot. The corrosion-resistant parts chosen are recorded, so they can be matched if anything is replaced later. Rinsing the cap with fresh water now and then slows the salt down.

Unit, vent route and trades on paper

  1. Service access panels left removable after the finish
  2. Gas supply to the shutoff valve, named with the trade that runs it
  3. Inlet and manifold pressures read and recorded at start-up
  4. Barrier screen fitted and logs set to the placement diagram

Gas fireplace install questions from Fernandina Beach

Do you run the gas line to the new fireplace?

No. The line to the unit's shutoff valve is a gas contractor's job, or the propane supplier's on a propane system. The estimate says who and when, and start-up follows once gas reaches the valve.

Will the vent termination be visible outside?

Yes, a wall termination is a cap on the outside wall at the spot the clearances allow. If the house is under an association, check its rules before the spot is final.