Fireplace repair in Bayard by local experts
Two lists for your Bayard fireplace from a free inspection, what needs fixing now and what can wait.
- Fully licensed and insured
- Locally owned
- Family owned and operated
- Same-day service
Get Your Free Inspection
Get a quote for chimney and fireplace repair and installation in Jacksonville.
Request received
Thank you. We will call you shortly to set a time.
Quicker by phone? Call (904) 920-5495
Fireplace repair pros for Bayard homes
- Locally owned in Jacksonville
- Family owned and operated
- 100% satisfaction guaranteed
- Free inspection and estimate
- Same-day service available
- 10% off any service
Firebox joints get refractory mortar, because ordinary mortar breaks down under the heat of a fire.
- Locally ownedA locally owned business shows you the failing part of your Bayard fireplace before any price.
- Upfront pricing, no hidden feesSafety repairs come first on the estimate, and items that can wait are priced on their own lines.
- 100% satisfaction guaranteedIf the fireplace still smokes or sticks after the repair we quoted for it, we come back.
Details that shorten the visit
A few details on the phone make the visit shorter. Tell us whether the fireplace is brick inside or has smooth panels, whether it burns wood, gas or nothing at all, and what you have noticed: smoke, a noise, a crack, a smell, a damper that will not move. If there is a metal plate inside the opening or behind a grille, read us the maker and model printed on it. With that, the visit to Bayard starts with the right parts list and the right questions, and the written estimate comes at the end of the same visit. A fireplace specialist can look at your Bayard fireplace for free; phone (904) 920-5495 to set it up.
Bayard lies within Duval County. Bayard sits away from the coastline.
What fireplace repair covers in Bayard
- Light test for gaps around a closed damper
- Trim and mantel distances checked against the code
- Rough smoke chamber parged smooth
- Unsafe items for your Bayard fireplace flagged in writing
Identify, test, repair, test fire
-
Type and rating plate read
We settle whether the fireplace is masonry or factory-built and read the model where there is one.
-
Joints, damper and hearth checked
Joints are probed, the damper worked through its travel, and the hearth and trim measured.
-
Repair with the right materials
Refractory mortar and firebrick for masonry, the maker's parts for factory-built units.
-
Test fire and cleanup
Where smoke was the problem, a short test fire checks the fix, and the room is cleaned before we go.
Hearths that crack in Bayard
A hearth that cracks straight across, with one side lower than the other, has lost support underneath. Resetting the tile does not fix that.
We check the slab under the hearth in Bayard homes and price the support repair when it is needed.
10% off any service booked within 72 hours of inspection
Comparing quotes? Three days is time enough to read ours beside another before you book.
Why firebox joints are kept a quarter inch wide
The building code limits the joints between firebricks to a quarter inch, and the reason is practical. Refractory mortar holds up to heat, but it is still the softest part of the lining, and a wide joint gives heat and flame more of it to work on. When we repoint a firebox, the old mortar is raked out to sound depth, the joint is cleaned and dampened as the mortar maker directs, and new medium-duty refractory mortar is packed in and struck flush. Joints that were laid wide to begin with cannot be narrowed without relaying the brick, so we note where that applies.
Raised hearths and the thinner extension
When the floor of the firebox sits at least 8 inches above the hearth extension, the code allows the extension to be thinner: at least 3/8 inch of approved noncombustible material instead of the 2 inches it otherwise requires. That exception is why a raised hearth can carry a thin stone or tile apron. It does not change how far the extension has to reach. A raised hearth that has been lowered, or a room where new flooring has built up the floor level, can take the fireplace out of the exception, so we measure the height as it stands today.
Working out how far trim can stand out
Trim near a masonry opening follows a simple ratio in the code: nothing combustible within 6 inches, and within 12 inches, no more than 1/8 inch of projection for each inch away from the opening. A piece of wood 8 inches from the opening may stand out 1 inch.
At 6 inches it may stand out three-quarters of an inch. Past 12 inches the ratio no longer applies. We measure each piece of trim and molding on the face, including the underside of a mantel shelf, and anything over the limit is listed with the fix, whether trimming it, moving it or replacing it with noncombustible material.
Parts, materials and safety items on paper
- Refractory panels ordered by model number from the rating plate
- Lintel over the opening checked for rust and lifted brick
- Outside air inlet screen and damper checked on factory-built units
- Grate size compared with the firebox and the maker's instructions
Fireplace repair questions from Bayard
Will you tell me if the fireplace is unsafe to use?
Yes, in writing. Faults such as an open firebox joint, a panel broken through to the steel or a damper that will not open go at the top of the estimate with a note to leave the fireplace unused until they are fixed.
Do you repair factory-built fireplaces as well as brick ones?
Yes. Factory-built units are repaired with the maker's parts, ordered from the model on the rating plate, so the fireplace stays within its listing. Brick fireplaces are repaired with firebrick and refractory mortar to the building code.
More services in Bayard
-
Ventless Gas Fireplace Service Oxygen depletion sensor pilots, burners and logs on vent-free units.
-
Chimney Crown Repair The concrete top of the chimney, sealed or recast so it sheds water again.
-
Gas Log Installation Vented and vent-free log sets set into sound wood-burning fireplaces.
-
Chimney Flashing Repair The metal joint between roof and chimney, re-formed so rain runs past it.
-
Top-Sealing Damper Installation A gasketed damper fitted at the flue top to replace a failed throat damper.
-
Firebox Repair Cracked firebrick and open refractory joints in a masonry firebox.
Learn more about fireplace repair and serviceAll services in Bayard
Fix the firebox, damper or hearth in Bayard
Our fireplace pros find what failed in your Bayard fireplace and write the fix down. Call (904) 920-5495.
Free Inspection